Skip to content
  • WELCOME TO MY SHOP
  • WELCOME TO MY SHOP
  • Home
  • Products
    • Actuator
    • Encoder
    • PLC Module
    • Solenoid Valve
    • Position Switch
    • Fieldbus Module
    • Frequency Converter
    • Water Quality Analyzer
    • Industrial Ethernet Switches
    • Other Industrial Accessories
  • Blogs
  • About Us
  • Contact Us
  • Login
  • Cart / $0.00
    • No products in the cart.

      Return to shop

  • Cart

    No products in the cart.

    Return to shop

1734-AENTR
Home / Products

1734-AENTR

  • Rockwell (Allen-Bradley) 1794-IF8IH analog input module,

Categories: PLC Module, Products Tag: 1734-AENTR
  • Rockwell (Allen-Bradley) 1794-IF8IH analog input module,
  • Description
  • Reviews (0)

Rockwell Automation (Allen-Bradley) PLC 1734-AENTR — A Deep Dive into Compact I/O Network Connectivity

When it comes to industrial automation, seamless communication between control systems and field devices is essential for maintaining efficiency, reliability, and safety. The Rockwell Automation Allen-Bradley PLC 1734-AENTR Ethernet/IP adapter stands out as a compact, high-performance solution that bridges these systems efficiently. Through its robust design, advanced networking capabilities, and flexible modular architecture, the 1734-AENTR module plays a vital role in distributed I/O systems that require fast data exchange and secure communication. For engineers and system integrators seeking dependable industrial networking, this module offers an ideal balance of scalability and reliability.

For more product details, users can explore related automation resources on www.ayingo.com, which provides technical insights into industrial control systems and components.


1. Overview of the 1734-AENTR Ethernet/IP Adapter

The Allen-Bradley 1734-AENTR is part of the POINT I/O family, which is known for its modular and space-efficient design. This Ethernet/IP adapter allows distributed I/O modules to connect directly to a control system over an Ethernet network, reducing wiring complexity and simplifying installation. With its dual Ethernet ports supporting Device Level Ring (DLR) topology, the 1734-AENTR ensures reliable network redundancy and continuous operation, even if one connection fails.

In addition, the module supports up to 63 I/O modules in a single assembly, providing exceptional scalability for small to medium-sized control applications. Whether it’s a manufacturing cell, packaging machine, or process control panel, the 1734-AENTR seamlessly integrates field I/O with a centralized PLC or PAC system.


2. Key Technical Specifications

The 1734-AENTR module comes with advanced features designed for performance and compatibility:

  • Network Interface: Dual-port 10/100 Mbps Ethernet/IP

  • Communication Protocol: EtherNet/IP (CIP – Common Industrial Protocol)

  • Supported Modules: Up to 63 POINT I/O modules

  • Redundancy: Device Level Ring (DLR) support for fault-tolerant operation

  • IP Address Configuration: BOOTP/DHCP, rotary switches, or web configuration

  • Power Requirements: 24V DC nominal (range 10–28.8V DC)

  • Diagnostics: Built-in status indicators for power, network, and module health

  • Dimensions: Compact design for DIN-rail mounting (approx. 2.76 x 0.47 x 2.36 in)

Every aspect of the adapter has been engineered for high-speed communication, robust network integrity, and long-term durability in harsh industrial environments.


3. Network Integration and Configuration Flexibility

One of the strongest advantages of the 1734-AENTR is its ease of integration within EtherNet/IP systems. The module supports direct connections with Rockwell’s ControlLogix and CompactLogix controllers, allowing engineers to quickly configure distributed I/O without complex programming. Moreover, it can be easily added to existing automation networks using standard Ethernet infrastructure.

The 1734-AENTR also provides web-based configuration tools, allowing users to monitor module status, view diagnostics, and set parameters through a standard browser interface. This feature helps reduce commissioning time and minimizes maintenance efforts.

Furthermore, with its DLR topology, users can ensure communication redundancy without additional switches. If a network break occurs, the adapter automatically reroutes communication through the alternate path, maintaining data flow and system reliability.


4. Enhanced Diagnostics and Maintenance Efficiency

In modern automation systems, predictive maintenance and rapid fault identification are key to reducing downtime. The 1734-AENTR includes advanced diagnostics that allow maintenance personnel to quickly detect and address potential issues. LED indicators display the status of power supply, network activity, and connection integrity, enabling real-time visibility into system performance.

Additionally, when integrated with Rockwell Automation software such as Studio 5000 Logix Designer, the module provides extended diagnostic information directly within the programming environment. As a result, engineers can troubleshoot network or module errors more efficiently, ensuring faster recovery and improved overall system uptime.


5. Application Scenarios and Industrial Use Cases

The Allen-Bradley 1734-AENTR Ethernet/IP adapter is widely used in industries that demand high flexibility and reliability. Its modular design and small footprint make it ideal for:

  • Machine automation: Compact I/O configurations for packaging, robotics, and material handling.

  • Process control: Distributed sensor and actuator integration in chemical, food, or water treatment plants.

  • Energy management systems: Integration of distributed data points for real-time monitoring.

  • OEM and panel builders: Simplified wiring and flexible system expansion for custom control solutions.

With growing trends toward Industrial IoT (IIoT) and smart manufacturing, the 1734-AENTR is increasingly valuable in systems that require both scalability and secure data communication over Ethernet/IP networks.


6. Advantages of the 1734-AENTR in Automation Systems

Unlike traditional centralized I/O systems, the POINT I/O architecture and the 1734-AENTR adapter offer significant operational advantages:

  • Modularity – Engineers can add or remove modules as needed, allowing easy system scaling.

  • Space Efficiency – Compact size minimizes control cabinet footprint.

  • Reduced Wiring Complexity – Ethernet-based communication replaces multiple cable runs.

  • Network Redundancy – Dual-port DLR ensures continuous operation.

  • Ease of Maintenance – Hot-swap capability allows module replacement without shutting down the system.

These benefits contribute directly to improved system uptime, reduced installation costs, and greater design flexibility — key goals in modern industrial automation.


7. System Compatibility and Future Scalability

The 1734-AENTR is fully compatible with Rockwell Automation’s Integrated Architecture, enabling smooth data flow from the device level to the enterprise level. It also supports standard Ethernet/IP communication, making it interoperable with third-party devices and software systems that comply with the CIP protocol.

As factories continue to adopt digital transformation strategies, the 1734-AENTR supports easy migration and expansion. Engineers can add additional I/O modules or upgrade network components without redesigning the entire system, ensuring long-term scalability.


8. Conclusion

The Rockwell Automation Allen-Bradley 1734-AENTR Ethernet/IP adapter is more than just a communication bridge — it’s a key enabler of flexible, efficient, and connected industrial control systems. Its modular design, redundant network capabilities, and ease of integration make it a cornerstone for engineers building distributed automation architectures.

For those seeking in-depth technical references and compatible industrial components, additional information can be found at www.ayingo.com, a resource hub for automation technology and system solutions.

By delivering reliable connectivity and advanced diagnostic functions, the 1734-AENTR continues to empower industries striving for smarter, faster, and more efficient control networks.

Reviews

There are no reviews yet.

Be the first to review “1734-AENTR” Cancel reply

Related products

SPDSI13
Quick View

Products

SPDSI13

IMHSS03
Quick View

Products

IMHSS03

PHARPS32200000
Quick View

Products

PHARPS32200000

IEMMU21
Quick View

Products

IEMMU21

PHARPSFAN03000
Quick View

Products

PHARPSFAN03000

RLM01
Quick View

Products

RLM01

Carlo Gavazzi Dupline® GTU8
Quick View

Products

Carlo Gavazzi Dupline® GTU8

PHARPS32000000
Quick View

Products

PHARPS32000000

CATEGORY
  • Fieldbus Module
  • PLC Module
  • Frequency Converter
  • Position Switch
  • Solenoid Valve
  • Actuator
  • Water Quality Analyzer
  • Industrial Ethernet Switches
  • Other Industrial Accessories
INFORMATION
  • Shipping Policy
  • Terms of Service
  • Privacy Policy
  • Return & Refund Policy
USEFUL LINKS
  • About Us
  • Contact Us
WHATSAPP
Copyright 2025 © Wuhan Yuli Automation Technology Co., Ltd
  • Home
  • Products
    • Actuator
    • Encoder
    • PLC Module
    • Solenoid Valve
    • Position Switch
    • Fieldbus Module
    • Frequency Converter
    • Water Quality Analyzer
    • Industrial Ethernet Switches
    • Other Industrial Accessories
  • Blogs
  • About Us
  • Contact Us
  • Login
  • Newsletter

Login

Lost your password?